PROPOSEDDynamite Construction has not asked for this. Every screen in this prototype is an Altumo proposal. Serves OPP-005

Mesh & drains

Projects › Skagit Bluff › Ground support › Mesh & drains

Slope mesh

AreaProductm² meshedSoil anchorsConformance docs
Zone 3TECCO62018prior to installation
Zone 4DELTAX84024prior to installation
Zone 5Draped mesh41011missing
Soil anchors are incidental to slope mesh and are not separately paid (SS 207.32) — recorded here for the physical record.
Mesh overlap is not separately paid (SS 207.81). Measurement is by the square metre of slope meshed area.

1,870 m² of a designated 2,400 m²partial payment available for completed portions.

Lined drains

LocationHolesTotal mPVC liningPayment
12+43014126documentedauthorised after installation

Other rockfall protection physical record

Attenuator fence · barrier fencing · rock bolting programs. Recorded for the record; measured under their own items where the contract has them.

Payment readiness Anchor register
Layout as specified in SCR-033-mesh-and-drains.md
┌──────────┬────────────────────────────────────────────────────┐
│ NAV      │ Skagit Bluff › Mesh & drains        [+ record]     │
│          ├────────────────────────────────────────────────────┤
│          │ SLOPE MESH                                         │
│          │ Area    Product   m² meshed  Anchors  Conform.     │
│          │ ────────────────────────────────────────────────   │
│          │ Zone 3  TECCO      620        18       ▨ prior     │
│          │ Zone 4  DELTAX     840        24       ▨ prior     │
│          │ Zone 5  drape      410        11       ⚠ missing   │
│          │  ⓘ soil anchors incidental — not separately paid   │
│          │  ⓘ overlap not separately paid                     │
│          │  1,870 m² of designated 2,400 m² · PARTIAL PAYMENT │
│          │    available for completed portions                │
│          ├────────────────────────────────────────────────────┤
│          │ LINED DRAINS                                       │
│          │ Location  Holes  Total m  PVC lining  Authorised   │
│          │ 12+430    14      126     ▨           ✔ after      │
│          │                                        installation│
│          ├────────────────────────────────────────────────────┤
│          │ OTHER ROCKFALL PROTECTION (physical record)        │
│          │ attenuator fence · barrier fencing · rock bolting  │
└──────────┴────────────────────────────────────────────────────┘

Implements spec/03-screens/SCR-033-mesh-and-drains.md · SCR-033 · URL /projects/{project}/mesh · Personas QC · Stories US-QC-012