PROPOSEDDynamite Construction has not asked for this. Every screen in this prototype is an Altumo proposal. Serves OPP-008
‹ back
⚠ OFFLINE

PRE-SHIFT INSPECTION · 27 Aug

Section 34.10 — inspected for defects by the person intending to use the system, before it is first used on each work shift. Not by a supervisor, not weekly, not once per job.

You: A. Singh — inspect the equipment you will use

HARNESS H-14 CSA Z259 / EN 361

DESCENDER D-07 EN 341

BACKUP DEVICE B-03

ROPE R-22, 60 m EN 1891

CONNECTORS C-31, C-32 CSA Z259.12 / EN 362

HEADGEAR HG-09

Manufacturer's required inspection: R-22 due 12 Sep

Tracked separately from the pre-shift check — the manufacturer's own manner and frequency also apply.

⚠ Found a defect?
Layout as specified in SCR-036-equipment-inspections.md
┌──────────────────────────────────────────────────────────────┐
│ ‹ back   PRE-SHIFT INSPECTION · 27 Aug     ⚠ OFFLINE         │
├──────────────────────────────────────────────────────────────┤
│  YOU: A. SINGH — inspect the equipment you will use          │
├──────────────────────────────────────────────────────────────┤
│  HARNESS  H-14  (CSA Z259 / EN 361)                          │
│   webbing ☐  stitching ☐  buckles ☐  attachment points ☐     │
│  DESCENDER D-07  (EN 341)                                    │
│   body ☐  cam ☐  handle ☐  markings legible ☐                │
│  BACKUP DEVICE B-03                                          │
│   body ☐  cam ☐  function test ☐                             │
│  ROPE  R-22, 60 m  (EN 1891)                                 │
│   sheath ☐  core feel ☐  terminations ☐  length ☐            │
│  CONNECTORS  C-31, C-32  (CSA Z259.12 / EN 362)              │
│   gate action ☐  locking ☐  wear ☐                           │
│  HEADGEAR  HG-09  chin strap 3-point ☐  shell ☐              │
├──────────────────────────────────────────────────────────────┤
│  Manufacturer's required inspection: R-22 due 12 Sep         │
├──────────────────────────────────────────────────────────────┤
│  ⚠ Found a defect?  [ REMOVE FROM SERVICE ]                  │
│    Returns only after inspection and RECERTIFICATION by the  │
│    manufacturer or a professional engineer (s. 34.16)        │
│                                    [ COMPLETE INSPECTION ]   │
└──────────────────────────────────────────────────────────────┘

Implements spec/03-screens/SCR-036-equipment-inspections.md · SCR-036 · Personas SUPV · Stories US-SUPV-004, US-SUPV-010