BOLT RB-118 · Skagit Bluff

Location12+462 L
Bolt numberRB-118
Length of bar in the rock6.0 m
Bondingresin · lot R-2231 · ≥90 MPa cured
Resin spinstart 09:12 · end 09:14
Equipmentjack JK-2 + pump PM-2 calibrated 14 Aug, valid to 13 Sep
Tester
Weather / temperatureovercast · 11 °C auto-filled from the nearest observation, confirmable
Creep test186 kN · hold 10 min · lock-off 140 kN

A torque wrench must not be used for tensioning.

min 1186min 6182
min 2185min 7182
min 3184min 8181
min 4184min 9— next in 0:37
min 5183min 10

Live acceptance

load loss 2.7%    (anchorage failure at > 10%)

head creep 0.8 mm    (must not exceed 2 mm)

Evaluated as the readings arrive — so a failing bolt is known before the crew moves on, not when the record is typed up.

If the lift-off load is not within 10% of the specified lock-off, a lift-off test of a different bolt is required.

Layout as specified in SCR-029-rock-bolt-test.md
┌───────────────────────────────────────────────────────────────┐
│ ‹ back    BOLT RB-118 · Skagit Bluff       ⚠ OFFLINE          │
├───────────────────────────────────────────────────────────────┤
│  BOLT      location 12+462 L · no. RB-118 · length 6.0 m      │
│  BONDING   resin ▾  lot ____   ⓘ ≥90 MPa cured (SS 206.05)    │
│   resin spin start [ 09:12 ]  end [ 09:14 ]                   │
│  EQUIPMENT jack JK-2 + pump PM-2 (calibrated pair)            │
│            calibrated 14 Aug · valid to 13 Sep ✔              │
│  TESTER    [ ______ ]                                         │
│  CONDITIONS weather [ overcast ] temperature [ 11 °C ]        │
│             (auto from nearest observation, confirm)          │
├───────────────────────────────────────────────────────────────┤
│  TEST      target 186 kN · hold 10 min · lock-off 140 kN      │
│            ⓘ torque wrench must not be used                   │
│            start [ 09:20 ]                                    │
│  ┌────────────────────────────────────────────────────────┐   │
│  │ min 1  [ 186 ] kN     min 6  [ 182 ] kN                │   │
│  │ min 2  [ 185 ]        min 7  [ 182 ]                   │   │
│  │ min 3  [ 184 ]        min 8  [ 181 ]                   │   │
│  │ min 4  [ 184 ]        min 9  [ ___ ]  ← next in 0:37   │   │
│  │ min 5  [ 183 ]        min 10 [ ___ ]                   │   │
│  └────────────────────────────────────────────────────────┘   │
│  LIVE   load loss 2.7% (fail >10%)   ✔                        │
│         head creep 0.8 mm (fail >2 mm) ✔                      │
├───────────────────────────────────────────────────────────────┤
│  end [ ____ ]   LOCK OFF at 140 kN  [ record ]                │
│  lift-off within 10% of lock-off? → else retest another bolt  │
└───────────────────────────────────────────────────────────────┘

Implements spec/03-screens/SCR-029-rock-bolt-test.md · SCR-029 · Personas QC · Stories US-QC-004