PROPOSEDDynamite Construction has not asked for this. Every screen in this prototype is an Altumo proposal. Serves OPP-001
‹ back
⚠ OFFLINE · the timer runs entirely on this device

MISFIRE HOLD · BL-15

Initiation system usedElectronic detonator
Regulation period30 minutes after disconnecting the firing lines and shunting the lead wires
Manufacturer's stated period
Holdthe later of the two

The countdown starts from the recorded act, not from opening this screen.

18:42

REMAINING — DO NOT ENTER THE DANGER AREA

⚠ Is a charge burning, or suspected burning?

The outcome of this hold is recorded in the blasting log alongside the post-blast examination.

Layout as specified in SCR-022-misfire-hold.md
┌──────────────────────────────────────────────────────────────┐
│ ‹ back        MISFIRE HOLD · BL-15          ⚠ OFFLINE        │
├──────────────────────────────────────────────────────────────┤
│                                                              │
│   INITIATION SYSTEM USED:  electronic detonator              │
│   Regulation period:       30 minutes                        │
│   after disconnecting firing lines and shunting lead wires   │
│                                                              │
│   Manufacturer's stated period: [ ____ min ]                 │
│   HOLD = the later of the two                                │
│                                                              │
│   ☐ Firing lines disconnected                                │
│   ☐ Lead wires shunted                                       │
│        [ START HOLD ]                                        │
│                                                              │
│   ┌────────────────────────────────────────────────────┐     │
│   │                                                    │     │
│   │                 18 : 42                            │     │
│   │        remaining — DO NOT ENTER THE DANGER AREA    │     │
│   │                                                    │     │
│   └────────────────────────────────────────────────────┘     │
│                                                              │
│   ⚠ IS A CHARGE BURNING OR SUSPECTED BURNING?                │
│     [ yes ] → hold becomes 1 hour AFTER SMOKE CLEARS,        │
│               or the manufacturer's period, whichever later  │
│                                                              │
│   Declared by ______ at ______                               │
│   Evidence / suspicion: [ ______________________________ ]   │
└──────────────────────────────────────────────────────────────┘

Implements spec/03-screens/SCR-022-misfire-hold.md · SCR-022 · Personas BLAST · Stories US-BLAST-004