MISFIRE HOLD · BL-15
| Initiation system used | Electronic detonator |
| Regulation period | 30 minutes after disconnecting the firing lines and shunting the lead wires |
| Manufacturer's stated period | |
| Hold | the later of the two |
The countdown starts from the recorded act, not from opening this screen.
18:42
REMAINING — DO NOT ENTER THE DANGER AREA
⚠ Is a charge burning, or suspected burning?
The hold becomes the later of one hour after the smoke clears and the manufacturer's stated period. The prior countdown is discarded.
The outcome of this hold is recorded in the blasting log alongside the post-blast examination.
Layout as specified in SCR-022-misfire-hold.md
┌──────────────────────────────────────────────────────────────┐ │ ‹ back MISFIRE HOLD · BL-15 ⚠ OFFLINE │ ├──────────────────────────────────────────────────────────────┤ │ │ │ INITIATION SYSTEM USED: electronic detonator │ │ Regulation period: 30 minutes │ │ after disconnecting firing lines and shunting lead wires │ │ │ │ Manufacturer's stated period: [ ____ min ] │ │ HOLD = the later of the two │ │ │ │ ☐ Firing lines disconnected │ │ ☐ Lead wires shunted │ │ [ START HOLD ] │ │ │ │ ┌────────────────────────────────────────────────────┐ │ │ │ │ │ │ │ 18 : 42 │ │ │ │ remaining — DO NOT ENTER THE DANGER AREA │ │ │ │ │ │ │ └────────────────────────────────────────────────────┘ │ │ │ │ ⚠ IS A CHARGE BURNING OR SUSPECTED BURNING? │ │ [ yes ] → hold becomes 1 hour AFTER SMOKE CLEARS, │ │ or the manufacturer's period, whichever later │ │ │ │ Declared by ______ at ______ │ │ Evidence / suspicion: [ ______________________________ ] │ └──────────────────────────────────────────────────────────────┘
Implements spec/03-screens/SCR-022-misfire-hold.md · SCR-022 · Personas BLAST · Stories US-BLAST-004