3 permanent anchors sit on sites we no longer work. The annual obligation does not end with the project — which is exactly where it gets missed.
IDSiteInstalledCapacityPE certifiedLast inspectionNext due
PA-04Skagit Bluff active2026-0830 kNanchor + installation2026-08Aug 2027
PA-03Vernon 35th St inactive2025-0226 kNanchor + installation2025-02OVERDUE — Feb 2026
PA-01Cameron Lake inactive2023-0730 kNanchor + installation2026-07Jul 2027

A permanent anchor must have an ultimate load capacity of at least 22.2 kN (5000 lbf) for each person connected, be inspected and tested at least once a year per CSA Z91-02 (R2013) with the results documented, and be certified by a professional engineer along with its installation.

Temporary anchors

Removed from service immediately after use. Minimum ultimate load capacity 12 kN (2700 lbf) per person connected. 14 recorded this year. No annual obligation.

System limit

A rope access system must limit maximum arrest force to not more than 6 kN (1350 lbf).

Obligation calendar
Layout as specified in SCR-037-anchor-register.md
┌──────────┬────────────────────────────────────────────────────┐
│ NAV      │ Anchor register       [ ✓ sites we still work ]    │
│          ├────────────────────────────────────────────────────┤
│          │ ⚠ 3 permanent anchors sit on sites we no longer    │
│          │   work. The annual obligation does not end with    │
│          │   the project.                                     │
│          ├────────────────────────────────────────────────────┤
│          │ ID     Site          Installed  Capacity  Next     │
│          │ ─────────────────────────────────────────────────  │
│          │ PA-04  Skagit Bluff   2026-08   30 kN     Aug 2027 │
│          │  PE certified ▨ · installation certified ▨         │
│          │  last inspection 2026-08 · CSA Z91-02 ▨ documented │
│          │ PA-03  Vernon 35th St 2025-02   26 kN  ⚠ OVERDUE   │
│          │  due Feb 2026 · site no longer active              │
│          │ PA-01  Cameron Lake   2023-07   30 kN     Jul 2027 │
│          │  site no longer active                             │
│          ├────────────────────────────────────────────────────┤
│          │ TEMPORARY ANCHORS (removed immediately after use)  │
│          │  ≥12 kN (2700 lbf) per person connected            │
│          │  no annual obligation — 14 recorded this year      │
│          ├────────────────────────────────────────────────────┤
│          │ Max arrest force any system may impose: 6 kN       │
└──────────┴────────────────────────────────────────────────────┘