Design — every SS 204.04.07 field
| Date prepared | 27 Aug 2026 |
| Proposed blast date | 3 Sep 2026 |
| Station limits | 12+400 to 12+540 |
| Free face | Existing bench, south |
| Burden | 2.4 m |
| Spacing | 2.1 m |
| Hole diameter | 76 mm |
| Hole angle | 15° |
| Lift height | 6.0 m |
| Drill offset | 0.3 m |
| Hole depth | 6.6 m |
| Subdrill | 0.6 m |
| Production holes (incl. buffer) | 44 |
| Backline holes | 18 |
| Loading | 230 kg emulsion · primers · initiators · stemming 1.8 m crushed aggregate |
| Initiation sequence | electronic · 17 ms inter-hole / 25 ms inter-row |
| Manufacturer data sheets | 4 attached explosives · primers · delays · initiators |
| Plan view | attached |
| Section view | attached |
Signatures — the design cannot complete without both
Independent under SS 204.03.02 — not an employee of the contractor, an explosives manufacturer or a distributor.
Printed name · company · certificate number recorded
The certificate number ties the plan to a person legally permitted to execute it. Checked against the qualification register on signing.
A change to previously used drilling or blasting methods is a new version, needing its own signature and a minimum of one day's notice.
Pre-blast survey — due at least one day before
| Kind | Identity | Distance | In proximity zone | Existing condition |
|---|---|---|---|---|
| Medical clinic | Vernon walk-in, 35th St | 280 m | yes — 300 m | recorded, 4 photographs |
| Occupied structure | 3412 35th St | 96 m | yes — 150 m | recorded, 6 photographs |
| Occupied structure | 3418 35th St | 104 m | yes | recorded |
| Well | Private, lot 22 | 88 m | surveyable, not notifiable | recorded |
| Utility | Buried gas main | 40 m | surveyable, not notifiable | located and marked |
Survey method recorded, and confirmed acceptable to the contractor's insurance company as SS 204.04.08 requires. The same structure list drives the 48-hour occupant notices — one geometry, two uses.
Close-proximity written plan — in force
| Author qualification | ≥5 years urban blasting · EGBC member in good standing |
| PPV limit | 3.0 mm/s |
| Frequency response limit | recorded |
| Air overpressure limit | recorded |
| Monitoring method | Seismograph between the blast area and the nearest structure |
Division 14 prescriptive conditions: blasting mats on all material hole ≤ 75 mm bench:burden ≥ 2:1 stemming: crushed aggregate no safety fuse
Layout as specified in SCR-019-blast-design.md
┌──────────┬────────────────────────────────────────────────────┐ │ NAV │ ‹ Blasting BL-15 · proposed 3 Sep [design ▾] │ │ ├────────────────────────────────────────────────────┤ │ │ DESIGN │ │ │ Station limits 12+400 to 12+540 │ │ │ Pattern plan ▨ section ▨ │ │ │ free face · burden 2.4 m · spacing 2.1 m · │ │ │ hole dia 76 mm · angle 15° · lift 6 m · │ │ │ drill offset 0.3 m · depth 6.6 m · subdrill 0.6 m │ │ │ Holes production ▨ buffer ▨ backline ▨ │ │ │ Loading type · amount · primers · initiators · │ │ │ stemming location and depth │ │ │ Initiation delay times · delay system │ │ │ Data sheets ▨ explosives ▨ primers ▨ delays ▨ init.│ │ ├────────────────────────────────────────────────────┤ │ │ SIGNATURES │ │ │ ☐ Blasting consultant ____ (independent — SS │ │ │ 204.03.02) · company ____ │ │ │ ☐ Blaster ____ · cert no. ____ · company ____ │ │ │ DESIGN CANNOT COMPLETE WITHOUT BOTH │ │ ├────────────────────────────────────────────────────┤ │ │ PRE-BLAST SURVEY (due ≥1 day before) │ │ │ 6 structures · 1 well · 2 utilities · method: ____ │ │ │ acceptable to our insurer ☐ │ │ ├────────────────────────────────────────────────────┤ │ │ CLOSE-PROXIMITY PLAN (in force) │ │ │ author ____ · ≥5 yrs urban · EGBC/ASTTBC/cert │ │ │ PPV ≤ 3.0 · freq ____ · air overpressure ____ │ │ │ mats ✔ · hole ≤75 mm ✔ · bench:burden ≥2:1 ✔ · │ │ │ stemming crushed aggregate ✔ · no safety fuse ✔ │ └──────────┴────────────────────────────────────────────────────┘