Calibrated equipment

Projects › Skagit Bluff › Ground support › Calibration
Two different dates. The certificate must be provided 5 working days before commencing rock bolt installation, and the calibration itself must have been performed not more than 30 days prior to rock bolt testing. Pumps and jacks must be paired for calibration.
PairCalibratedValid for testing toAgencyCertificateState
JK-2 + PM-214 Aug13 Sepauthorised testing agencygauge-pressure ↔ applied-load curvein window
JK-1 + PM-12 Jul1 Augauthorised testing agencyattachedout of window
JK-3not paired
A test performed with an out-of-window pair produces a record that will not release payment. So an out-of-window pair cannot be selected on a rock bolt test at all.

The certificate's gauge-pressure to applied-load relationship is what makes a minute-by-minute gauge reading mean anything. Calibration expiries appear in the obligation calendar.

Open a test
Layout as specified in SCR-046-calibrated-equipment.md
┌──────────┬────────────────────────────────────────────────────┐
│ NAV      │ Skagit Bluff › Calibration          [+ pair]       │
│          ├────────────────────────────────────────────────────┤
│          │ Pair       Calibrated  Valid to  Agency  Cert      │
│          │ ────────────────────────────────────────────────   │
│          │ JK-2 + PM-2  14 Aug     13 Sep    ____    ▨        │
│          │   gauge pressure ↔ applied load curve ▨            │
│          │   ✔ certificate submitted 5 working days before    │
│          │     installation commenced                         │
│          │ JK-1 + PM-1  02 Jul     01 Aug   ____    ▨         │
│          │   ⚠ OUT OF WINDOW — cannot be used for testing     │
│          │     recalibrate before use                         │
│          │ JK-3         —          —         —      —         │
│          │   ⚠ NOT PAIRED — pumps and jacks must be paired    │
│          │     for calibration                                │
│          ├────────────────────────────────────────────────────┤
│          │ ⓘ A test performed with an out-of-window pair      │
│          │   produces a record that will not release payment. │
│          │ Calibration expiries appear in the obligation      │
│          │ calendar.                                          │
└──────────┴────────────────────────────────────────────────────┘

Implements spec/03-screens/SCR-046-calibrated-equipment.md · SCR-046 · URL /projects/{project}/calibration · Personas QC · Stories US-QC-010